SG-Ready startup grace period (sg_ready_startup_min: 10): Heat pump compressor takes ~9 minutes to start after receiving the SG-Ready signal. Previously, idle detection fired after only 3×2min=6min, turning off SG-Ready before the compressor had time to respond. The grace period suppresses idle detection for the configured duration after activation. 0 = disabled (tests and unconfigured deployments are unaffected). Daily PV yield (photovoltaic_production_cumulated_currentDay): Reads actual kWh produced today from Prometheus (Wh → kWh, ÷1000). Logged as pv_today_kwh each cycle. Shown on status page in two places: - PV card sub-line: "Heute: 31.9 kWh" - Forecast card alongside forecast: "Ist: 31.9 kWh" Immediately makes forecast vs reality visible (today: forecast 15.9, actual 31.9 kWh — explains why SOC bypass triggered). Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>