- Replace reactive export-threshold wallbox activation with proactive logic: WallboxA/B activate when forecast ≥ mid AND PV ≥ threshold AND SOC ≥ 35%, without requiring grid export surplus - Add WallboxB no-car detection via grid-delta probe (no PM available): after probe window, if grid shift < GridDeltaThreshW → no car, retry after configured timeout - Add EOD soft stop: after 16:00, stop proactive car charging if remaining PV estimate can't cover battery deficit to 90% by sunset - WW boost no longer requires export threshold; dynamic setpoint uses tank top temp + hysteresis + boost delta, capped at 60°C - Proactive wallboxes bypass import-hysteresis shutdown; SOC emergency brake uses SOCFloor (5%) instead of standard AllConsumers gate - Add WWTopTempC to SystemState (ww_top_temp metric from DHW cylinder) - Add BatteryConfig (capacity_kwh), CarChargingConfig to config - Add WWMaxSetpointC, WWHysteresisC to StrategicConfig - Update Decide() signature: forecastKWh + sunsetTime parameters - Update all tests; add proactive charging test cases Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>