Lutz Finsterle 7a971c4c41 Add configurable override duration and hard-stop thresholds
Override duration (web UI):
- Dropdown on Ein button: 30min / 1h / 2h / 4h
- Engine notified immediately via ApplyOverride() — no waiting for
  next SyncHardwareState cycle
- Aus button always uses 1h lockout (keeps consumer off for 1h)

Hard-stop thresholds that cancel active overrides:
- SOC emergency brake: now also clears ManualOverride flag so EMS
  resumes full control after the safety shutdown
- override_max_import_w (default 800W): if grid import exceeds this
  while an override is active, override is cancelled immediately
  (no hysteresis delay — protection is instant)

Config: ems.override_max_import_w (0 = disabled)