Lutz Finsterle 971e22c4be Implement proactive forecast-driven car charging strategy
- Replace reactive export-threshold wallbox activation with proactive
  logic: WallboxA/B activate when forecast ≥ mid AND PV ≥ threshold
  AND SOC ≥ 35%, without requiring grid export surplus
- Add WallboxB no-car detection via grid-delta probe (no PM available):
  after probe window, if grid shift < GridDeltaThreshW → no car, retry
  after configured timeout
- Add EOD soft stop: after 16:00, stop proactive car charging if
  remaining PV estimate can't cover battery deficit to 90% by sunset
- WW boost no longer requires export threshold; dynamic setpoint uses
  tank top temp + hysteresis + boost delta, capped at 60°C
- Proactive wallboxes bypass import-hysteresis shutdown; SOC emergency
  brake uses SOCFloor (5%) instead of standard AllConsumers gate
- Add WWTopTempC to SystemState (ww_top_temp metric from DHW cylinder)
- Add BatteryConfig (capacity_kwh), CarChargingConfig to config
- Add WWMaxSetpointC, WWHysteresisC to StrategicConfig
- Update Decide() signature: forecastKWh + sunsetTime parameters
- Update all tests; add proactive charging test cases

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>