009f8b05f3 Stack WW boost buttons vertically in consumer card
The reset and boost toggle buttons were side by side, looking cramped.
Wrapped them in a flex column div so they stack neatly below each other.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-06 16:23:27 +02:00
4d4b7fb047 Fix WW boost toggle: move WWBoostDisabled into consumerView
Template range loop sets . to consumerView, not pageData, so
.WWBoostDisabled was undefined. Added the field to consumerView
and populated it from the wwBoostDisabled local in the handler.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-06 16:18:18 +02:00
afbb7bf62c Add WW boost enable/disable toggle (persistent flag file)
In summer the WW boost interferes with car charging priority.
A new / toggle on the WW consumer card persists to
/etc/ems/ww-boost-off (presence = disabled, absence = enabled).

- config: ww_boost_disable_file flag file path
- main: wwBoostDisabled mode, wwBoostToggleHandler, runCycle skips
  computeWWBoost when disabled
- status: WWBoostDisabled in pageData, toggle button in WW card
  showing  Boost aus /  Boost ein depending on state

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-06 16:09:33 +02:00
1b57293da9 Fix compressor watts, add WW boost reset button
Compressor:
- metric changed to PromQL expression that returns actual watts:
  sensors_power_value(%) × power_value(kW) × 10
  e.g. 27% × 10 kW = 2700 W; idle = 0 W
- idle threshold raised 20→500 W (clean gap: 0W idle vs ≥2700W running)
- status page now displays real kW instead of percent

WW boost reset:
- Added 🌡️ Zurücksetzen button to WW consumer card (when configured)
- POST /ww/reset: restores WWBaseC via Viessmann API + blocks re-boost
  via engine override until midnight
- IsWW field added to consumerView for template control

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-06 16:00:42 +02:00
406046c3a9 Add trip mode: self-learning EV charging scheduler
User enters car SOC + departure deadline; EMS computes when to start
charging and activates the wallbox at the right time (grid import OK
for trip mode). Charging rate is learned from completed PM sessions,
improving over time. Car profiles (Mini Cooper SE 50 kWh, BMW ix2 63
kWh) are config-driven and selectable per trip.

- internal/trip/trip.go: Goal/Session types, Manager with per-cycle
  Tick() that accumulates energy, detects session completion, learns
  avg charge rate from JSONL session log
- internal/config: CarProfile + Cars map, TripGoalFile, SessionLogFile
- internal/status: trip card (active goal) + trip form (set new goal),
  CarOption list, formatDay/formatDur helpers
- main.go: tripMgr lifecycle, /trip + /trip/cancel HTTP handlers,
  runCycle integration (ShouldStartNow → ApplyOverride, auto-clear)
- configs/ems-config.yaml: cars section, trip_goal_file, session_log_file

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-06 12:51:41 +02:00
00f8f3cdde Add monitor-only mode: suppress all actions without stopping EMS
New internal/monitor package provides a thread-safe, file-backed toggle.
Flag file presence (/etc/ems/monitor-only) = monitor-only active, survives
reboots. Deletion = resume normal operation.

Behaviour when active:
- EMS continues polling Prometheus, running the decision engine, and
  updating the status page every 2 minutes — full visibility maintained
- All actuator calls suppressed (Shelly switches + Viessmann WW writes)
- Suppressed actions logged as [MONITOR-ONLY] for audit trail
- Startup warns if flag file is already present

Web UI:
- Amber banner "⏸ Monitor-Only — Keine Schaltvorgänge" with inline
  "▶ Automatik" resume button when active
- Small unobtrusive "⏸ Monitor-Only" button at page bottom when inactive
- POST /monitor endpoint toggles state and redirects back to status page

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-06 11:27:53 +02:00
cc33add507 Show consumer priority order on status page
Section title changed to "Verbraucher — Priorität ↓" and each consumer
row now shows a circled number (① ② ③ ④) so it's immediately clear
which consumer has precedence for turn-on and reverse order for shutdown.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-06 11:08:34 +02:00
7a971c4c41 Add configurable override duration and hard-stop thresholds
Override duration (web UI):
- Dropdown on Ein button: 30min / 1h / 2h / 4h
- Engine notified immediately via ApplyOverride() — no waiting for
  next SyncHardwareState cycle
- Aus button always uses 1h lockout (keeps consumer off for 1h)

Hard-stop thresholds that cancel active overrides:
- SOC emergency brake: now also clears ManualOverride flag so EMS
  resumes full control after the safety shutdown
- override_max_import_w (default 800W): if grid import exceeds this
  while an override is active, override is cancelled immediately
  (no hysteresis delay — protection is instant)

Config: ems.override_max_import_w (0 = disabled)

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-06 10:43:49 +02:00
0020f1268b Add EV charging advice notification to status page
Uses hourly PV forecast data (watts per hour from forecast.solar) to
find the first contiguous block of hours where:
  PV production - base_load_w >= min_surplus_w

Shows a blue advice card on the status page:
  "Auto einstecken bis HH:MM Uhr"
  "Erwartetes Überschuss-Fenster: HH:MM – HH:MM Uhr"

Card is hidden when:
- No surplus window found (weak forecast day)
- Window has already started or passed
- A wallbox is currently active (car already charging)

Config: forecast.base_load_w (1000W), forecast.min_surplus_w (1800W)
Timestamp parsing handles both "HH:MM:SS" and "HH:MM" key formats.
Today: surplus window 11:00–13:00 (24.3 kWh forecast).

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-06 10:30:58 +02:00
79828a46c5 Add status page enhancements and engine improvements
Status page:
- Per-phase grid power (L1/L2/L3) with export/import direction
- Shelly PM live power badge on active wallbox rows
- Compressor power shown below consumer list
- SyncDeviceStates() method on Store for PM power readback

Engine:
- Fix wallbox mutex: re-read Active state after P3 so same-cycle
  WallboxA activation correctly blocks WallboxB in P4
- Fix RecoverState: set ActivatedAt to zero so recovered consumers
  are immediately eligible for shutdown decisions
- Add 3 new unit tests: mutual exclusion, car-not-charging,
  compressor-idle early release

Makefile:
- make install no longer overwrites /etc/ems/ems-config.yaml if it
  already exists (prevents password loss on updates)

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-06 10:06:01 +02:00
99613c52ae Initial commit: EMS — Energie Management System
Complete self-consumption optimisation system for 7 kWp PV installation:
- Prometheus collector (grid power, SOC, PV, per-phase, compressor)
- Pure decision engine with SOC gates, hysteresis, priority ordering
- Shelly Gen1/Gen2 actuator (SHA-256 Digest auth, PM power readback)
- Viessmann OAuth2 client for DHW temperature control
- PV forecast integration (forecast.solar)
- Wallbox mutual exclusion (VX3 4.6 kW AC output constraint)
- Car-not-charging detection via Shelly PM
- Compressor idle → early SG-Ready release
- Per-phase grid power for single-phase wallbox decisions
- Manual override detection and web UI with override buttons
- Full unit test coverage for decision engine
- systemd service, Makefile, complete documentation

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-06 10:02:16 +02:00