Commit Graph

6 Commits

Author SHA1 Message Date
00f8f3cdde Add monitor-only mode: suppress all actions without stopping EMS
New internal/monitor package provides a thread-safe, file-backed toggle.
Flag file presence (/etc/ems/monitor-only) = monitor-only active, survives
reboots. Deletion = resume normal operation.

Behaviour when active:
- EMS continues polling Prometheus, running the decision engine, and
  updating the status page every 2 minutes — full visibility maintained
- All actuator calls suppressed (Shelly switches + Viessmann WW writes)
- Suppressed actions logged as [MONITOR-ONLY] for audit trail
- Startup warns if flag file is already present

Web UI:
- Amber banner "⏸ Monitor-Only — Keine Schaltvorgänge" with inline
  "▶ Automatik" resume button when active
- Small unobtrusive "⏸ Monitor-Only" button at page bottom when inactive
- POST /monitor endpoint toggles state and redirects back to status page

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-06 11:27:53 +02:00
cc33add507 Show consumer priority order on status page
Section title changed to "Verbraucher — Priorität ↓" and each consumer
row now shows a circled number (① ② ③ ④) so it's immediately clear
which consumer has precedence for turn-on and reverse order for shutdown.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-06 11:08:34 +02:00
7a971c4c41 Add configurable override duration and hard-stop thresholds
Override duration (web UI):
- Dropdown on Ein button: 30min / 1h / 2h / 4h
- Engine notified immediately via ApplyOverride() — no waiting for
  next SyncHardwareState cycle
- Aus button always uses 1h lockout (keeps consumer off for 1h)

Hard-stop thresholds that cancel active overrides:
- SOC emergency brake: now also clears ManualOverride flag so EMS
  resumes full control after the safety shutdown
- override_max_import_w (default 800W): if grid import exceeds this
  while an override is active, override is cancelled immediately
  (no hysteresis delay — protection is instant)

Config: ems.override_max_import_w (0 = disabled)

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-06 10:43:49 +02:00
0020f1268b Add EV charging advice notification to status page
Uses hourly PV forecast data (watts per hour from forecast.solar) to
find the first contiguous block of hours where:
  PV production - base_load_w >= min_surplus_w

Shows a blue advice card on the status page:
  "Auto einstecken bis HH:MM Uhr"
  "Erwartetes Überschuss-Fenster: HH:MM – HH:MM Uhr"

Card is hidden when:
- No surplus window found (weak forecast day)
- Window has already started or passed
- A wallbox is currently active (car already charging)

Config: forecast.base_load_w (1000W), forecast.min_surplus_w (1800W)
Timestamp parsing handles both "HH:MM:SS" and "HH:MM" key formats.
Today: surplus window 11:00–13:00 (24.3 kWh forecast).

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-06 10:30:58 +02:00
79828a46c5 Add status page enhancements and engine improvements
Status page:
- Per-phase grid power (L1/L2/L3) with export/import direction
- Shelly PM live power badge on active wallbox rows
- Compressor power shown below consumer list
- SyncDeviceStates() method on Store for PM power readback

Engine:
- Fix wallbox mutex: re-read Active state after P3 so same-cycle
  WallboxA activation correctly blocks WallboxB in P4
- Fix RecoverState: set ActivatedAt to zero so recovered consumers
  are immediately eligible for shutdown decisions
- Add 3 new unit tests: mutual exclusion, car-not-charging,
  compressor-idle early release

Makefile:
- make install no longer overwrites /etc/ems/ems-config.yaml if it
  already exists (prevents password loss on updates)

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-06 10:06:01 +02:00
99613c52ae Initial commit: EMS — Energie Management System
Complete self-consumption optimisation system for 7 kWp PV installation:
- Prometheus collector (grid power, SOC, PV, per-phase, compressor)
- Pure decision engine with SOC gates, hysteresis, priority ordering
- Shelly Gen1/Gen2 actuator (SHA-256 Digest auth, PM power readback)
- Viessmann OAuth2 client for DHW temperature control
- PV forecast integration (forecast.solar)
- Wallbox mutual exclusion (VX3 4.6 kW AC output constraint)
- Car-not-charging detection via Shelly PM
- Compressor idle → early SG-Ready release
- Per-phase grid power for single-phase wallbox decisions
- Manual override detection and web UI with override buttons
- Full unit test coverage for decision engine
- systemd service, Makefile, complete documentation

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-06 10:02:16 +02:00