Fix proactive charging, logging, and status page ordering
1. SOC high bypass: when SOC >= soc_high_bypass_pct (default 90%), activate car charging without requiring a good forecast. Solves today's missed charging window where 4kW was exported for 6h with a full battery because the intraday forecast dropped from 15.4 to 13.3 kWh. 2. Log ambient_c in every cycle: makes it diagnosable why isHeatingPeriod suppresses SG-Ready on warm days (heating_min_ambient_c: 15°C gate). 3. Consumer names in logs: replace slog integer Consumer values with .String() so logs show "wallbox_a" instead of "2". 4. Status page order: reorder consumers by EMS priority (WallboxA → WallboxB → WW → SG-Ready) instead of the old reversed order. Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
This commit is contained in:
@@ -260,8 +260,22 @@ func (e *Engine) evaluateCarCharging(state collector.SystemState, forecastKWh fl
|
||||
return nil
|
||||
}
|
||||
|
||||
// Forecast must be available and meet the minimum threshold (mid = worthwhile day)
|
||||
if forecastKWh == 0 || forecastKWh < float64(e.cfg.Strategic.ForecastMidKWh) {
|
||||
// Determine activation gate: either forecast is good, or SOC is already high
|
||||
// (battery full → activate regardless of forecast; any PV surplus should charge the car).
|
||||
socHighBypass := float64(cc.SOCHighBypassPct)
|
||||
if socHighBypass == 0 {
|
||||
socHighBypass = 90 // default: bypass forecast check when battery ≥ 90%
|
||||
}
|
||||
forecastOK := forecastKWh > 0 && forecastKWh >= float64(e.cfg.Strategic.ForecastMidKWh)
|
||||
socHigh := state.BatterySOC >= socHighBypass
|
||||
|
||||
if !forecastOK && !socHigh {
|
||||
e.logger.Debug("proactive car charging: skipped",
|
||||
"forecast_kwh", forecastKWh,
|
||||
"forecast_threshold", e.cfg.Strategic.ForecastMidKWh,
|
||||
"soc", state.BatterySOC,
|
||||
"soc_bypass_pct", socHighBypass,
|
||||
)
|
||||
return nil
|
||||
}
|
||||
|
||||
@@ -297,10 +311,14 @@ func (e *Engine) evaluateCarCharging(state collector.SystemState, forecastKWh fl
|
||||
csA.ProactiveCharging = true
|
||||
csA.LowPowerCycles = 0
|
||||
delete(e.hyst.ExportSinceAbove, ConsumerWallboxA)
|
||||
return []Action{{
|
||||
trigger := fmt.Sprintf("forecast %.1fkWh", forecastKWh)
|
||||
if socHigh && !forecastOK {
|
||||
trigger = fmt.Sprintf("SOC %.0f%% ≥ %.0f%% (bypass)", state.BatterySOC, socHighBypass)
|
||||
}
|
||||
return []Action{{
|
||||
Consumer: ConsumerWallboxA,
|
||||
TurnOn: true,
|
||||
Reason: fmt.Sprintf("proactive: PV %.0fW ≥ %.0fW, forecast %.1fkWh, SOC %.0f%%", state.PVProductionW, cc.PVThresholdAW, forecastKWh, state.BatterySOC),
|
||||
Reason: fmt.Sprintf("proactive: PV %.0fW ≥ %.0fW, %s", state.PVProductionW, cc.PVThresholdAW, trigger),
|
||||
}}
|
||||
}
|
||||
}
|
||||
@@ -330,10 +348,14 @@ func (e *Engine) evaluateCarCharging(state collector.SystemState, forecastKWh fl
|
||||
csB.ProbeStartGridW = state.GridPowerW
|
||||
csB.LowPowerCycles = 0
|
||||
delete(e.hyst.ExportSinceAbove, ConsumerWallboxB)
|
||||
trigger := fmt.Sprintf("forecast %.1fkWh", forecastKWh)
|
||||
if socHigh && !forecastOK {
|
||||
trigger = fmt.Sprintf("SOC %.0f%% ≥ %.0f%% (bypass)", state.BatterySOC, socHighBypass)
|
||||
}
|
||||
return []Action{{
|
||||
Consumer: ConsumerWallboxB,
|
||||
TurnOn: true,
|
||||
Reason: fmt.Sprintf("proactive: PV %.0fW ≥ %.0fW, forecast %.1fkWh, SOC %.0f%%", state.PVProductionW, cc.PVThresholdBW, forecastKWh, state.BatterySOC),
|
||||
Reason: fmt.Sprintf("proactive: PV %.0fW ≥ %.0fW, %s", state.PVProductionW, cc.PVThresholdBW, trigger),
|
||||
}}
|
||||
}
|
||||
}
|
||||
@@ -545,7 +567,7 @@ func (e *Engine) evaluateTurnOn(
|
||||
|
||||
// All conditions met — turn on
|
||||
e.logger.Info("turning on consumer",
|
||||
"consumer", consumer,
|
||||
"consumer", consumer.String(),
|
||||
"grid_w", gridW,
|
||||
"threshold", threshold,
|
||||
"export_duration", exportDuration,
|
||||
@@ -581,7 +603,7 @@ func (e *Engine) shutdownLastConsumer(now time.Time, gridW float64) *Action {
|
||||
// Manually overridden to ON — don't shut down until override expires
|
||||
if cs.ManualOverride && now.Before(cs.OverrideUntil) {
|
||||
e.logger.Debug("skipping shutdown, consumer is manually overridden",
|
||||
"consumer", c,
|
||||
"consumer", c.String(),
|
||||
"override_until", cs.OverrideUntil.Format("15:04"),
|
||||
)
|
||||
continue
|
||||
@@ -590,7 +612,7 @@ func (e *Engine) shutdownLastConsumer(now time.Time, gridW float64) *Action {
|
||||
// Proactive wallboxes are not shut down by import hysteresis.
|
||||
// Their stops are handled by EOD soft stop, no-car probe, and idle cycles.
|
||||
if cs.ProactiveCharging && (c == ConsumerWallboxA || c == ConsumerWallboxB) {
|
||||
e.logger.Debug("skipping shutdown, proactive car charging active", "consumer", c)
|
||||
e.logger.Debug("skipping shutdown, proactive car charging active", "consumer", c.String())
|
||||
continue
|
||||
}
|
||||
|
||||
@@ -605,7 +627,7 @@ func (e *Engine) shutdownLastConsumer(now time.Time, gridW float64) *Action {
|
||||
}
|
||||
if acceptedImportW > 0 && gridW <= acceptedImportW {
|
||||
e.logger.Debug("skipping shutdown, import within accepted tolerance",
|
||||
"consumer", c,
|
||||
"consumer", c.String(),
|
||||
"grid_w", gridW,
|
||||
"accepted_import_w", acceptedImportW,
|
||||
)
|
||||
@@ -616,7 +638,7 @@ func (e *Engine) shutdownLastConsumer(now time.Time, gridW float64) *Action {
|
||||
runtime := now.Sub(cs.ActivatedAt)
|
||||
if runtime < minRuntime {
|
||||
e.logger.Debug("skipping shutdown, min runtime not reached",
|
||||
"consumer", c,
|
||||
"consumer", c.String(),
|
||||
"runtime", runtime,
|
||||
"min_runtime", minRuntime,
|
||||
)
|
||||
@@ -624,7 +646,7 @@ func (e *Engine) shutdownLastConsumer(now time.Time, gridW float64) *Action {
|
||||
}
|
||||
|
||||
e.logger.Info("shutting down consumer",
|
||||
"consumer", c,
|
||||
"consumer", c.String(),
|
||||
"runtime", runtime,
|
||||
)
|
||||
|
||||
@@ -669,7 +691,7 @@ func (e *Engine) socEmergencyBrake(soc float64, now time.Time) []Action {
|
||||
}
|
||||
|
||||
e.logger.Warn("SOC emergency brake",
|
||||
"consumer", c,
|
||||
"consumer", c.String(),
|
||||
"soc", soc,
|
||||
"was_override", cs.ManualOverride,
|
||||
)
|
||||
@@ -708,7 +730,7 @@ func (e *Engine) overrideHardStop(gridW float64) []Action {
|
||||
}
|
||||
|
||||
e.logger.Warn("override hard stop: import exceeds limit",
|
||||
"consumer", c,
|
||||
"consumer", c.String(),
|
||||
"grid_w", gridW,
|
||||
"limit_w", limit,
|
||||
)
|
||||
@@ -748,7 +770,7 @@ func (e *Engine) ApplyOverride(consumer Consumer, on bool, duration time.Duratio
|
||||
cs.ActivatedAt = time.Time{}
|
||||
}
|
||||
e.logger.Info("manual override applied",
|
||||
"consumer", consumer,
|
||||
"consumer", consumer.String(),
|
||||
"on", on,
|
||||
"duration", duration,
|
||||
"until", cs.OverrideUntil.Format("15:04"),
|
||||
@@ -943,7 +965,7 @@ func (e *Engine) SyncHardwareState(states map[Consumer]DeviceStatus, now time.Ti
|
||||
if cs.Active != status.On {
|
||||
// External change detected
|
||||
e.logger.Info("manual override detected — external state change",
|
||||
"consumer", c,
|
||||
"consumer", c.String(),
|
||||
"engine_state", cs.Active,
|
||||
"hardware_state", status.On,
|
||||
"override_until", now.Add(overrideTimeout).Format("15:04"),
|
||||
@@ -961,7 +983,7 @@ func (e *Engine) SyncHardwareState(states map[Consumer]DeviceStatus, now time.Ti
|
||||
// Override expired and state matches — resume EMS control
|
||||
cs.ManualOverride = false
|
||||
cs.OverrideUntil = time.Time{}
|
||||
e.logger.Info("manual override expired, resuming EMS control", "consumer", c)
|
||||
e.logger.Info("manual override expired, resuming EMS control", "consumer", c.String())
|
||||
}
|
||||
|
||||
// Track low-power cycles for car-not-charging detection (PM devices only).
|
||||
@@ -970,7 +992,7 @@ func (e *Engine) SyncHardwareState(states map[Consumer]DeviceStatus, now time.Ti
|
||||
if cs.Active && status.PowerW < float64(e.cfg.Consumers.WallboxMinChargeW) {
|
||||
cs.LowPowerCycles++
|
||||
e.logger.Debug("wallbox low power cycle",
|
||||
"consumer", c,
|
||||
"consumer", c.String(),
|
||||
"power_w", status.PowerW,
|
||||
"low_power_cycles", cs.LowPowerCycles,
|
||||
)
|
||||
|
||||
Reference in New Issue